CO2 loading capacity measurement
https://doi.org/10.1016/j.ccst.2022.100028 “The CO2 loading capacity measurements were carried out by using a gas absorption setup that is shown in Fig. 2. The equipment description and calculation of CO2 loading
https://doi.org/10.1016/j.ccst.2022.100028 “The CO2 loading capacity measurements were carried out by using a gas absorption setup that is shown in Fig. 2. The equipment description and calculation of CO2 loading
https://doi.org/10.1016/j.ccst.2022.100040 “New CO2 absorbents pentane-3-oxy-1,5-diyl dimethyl dicarbonate (DC2, 98%) and octane-3,6-dioxy-1,8-diyl dimethyl dicarbonate (DC3, 96%) were provided by Chengdu Organic Research Institute, which has been reported
https://doi.org/10.1007/s13369-015-2008-z 2.1 Laboratory Setup For continuous CO2 removal from flue gas, a special laboratory unit was constructed. The most important parameters of the unit are
https://doi.org/10.1016/j.egypro.2017.03.1277 “The experiments were performed in a bench scale full cycle CO2 capture pilot plant shown in Fig. 1. The absorption and regeneration columns were
https://doi.org/10.1016/j.egypro.2017.03.1312 “2.1. Rotating Packed Bed (RPB). This was manufactured from PEEK, polypropylene and 316L stainless steel. The inner diameter of the bed was 80mm and
https://doi.org/10.1016/j.egypro.2017.03.1322 “Figure 1 shows the small-scale experimental apparatus of CO2 capture and recovery. It consists of one pair of absorber and stripper circulating an amine
https://doi.org/10.1016/j.egypro.2017.03.1211 “A solvent screening setup (S.S.S.) as shown in figure 1 constituting six glass reactors (V=250mL ± 0.5) was used for the CO2 absorption experiments.
https://doi.org/10.1039/C7RA01352C “Table 2 provides a list of published works related to the determining of KGCO2aV in absorber packed columns operated in low-pressure conditions. For each list, detailed information
https://doi.org/10.1155/2015/965015 “Figure 2 illustrates the methodology proposed to determine the chemical and physical absorbing capacity of solvents. The apparatus consists of a gas bubbler setup
https://doi.org/10.1016/j.petlm.2016.11.002 “Four sets of experiments were performed: heating and cooling profiles, comparison of conventional and microwave regeneration, CO2 absorption isotherms and multiple microwave regeneration cycles. For
© 2022 Science-Share.com.All Rights Reserved.
Cookie | Duration | Description |
---|---|---|
cookielawinfo-checkbox-analytics | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Analytics". |
cookielawinfo-checkbox-functional | 11 months | The cookie is set by GDPR cookie consent to record the user consent for the cookies in the category "Functional". |
cookielawinfo-checkbox-necessary | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookies is used to store the user consent for the cookies in the category "Necessary". |
cookielawinfo-checkbox-others | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Other. |
cookielawinfo-checkbox-performance | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Performance". |
viewed_cookie_policy | 11 months | The cookie is set by the GDPR Cookie Consent plugin and is used to store whether or not user has consented to the use of cookies. It does not store any personal data. |